This pH combination electrode is made of sensitive glass membrane with low impedance.It can be used in a variety of PH measurements with fast response, good thermal stability. It has the good reproducibility, difficult to hydrolysis, and basically eliminate the alkali error. In 0 to 14pH range, the output voltage of the electrode is linear. The reference system which consist of the Ag/AgCl gel electrolyte salt bridge has a stable half-cell potential and excellent anti-pollution performance. The ring PTFE membrane is not easy to be clogged, so the electrode is suitable for long-term online detection.
 
Q: How to use it in the Arduino water quality monitoring system?
A: This industial ph electrode can directly work with the sensor board from Analog pH Meter Kit to produce a long-term PH monitoring. And the output voltage feedbak is from 0 to 5v to indicate PH value from 0 to 14.
 
Applications
 
The electrode is suitable for all kinds of printing, circuit board factory, waste water containing chromium and other industrial and domestic sewage pH monitoring.
 
Specification
  • Length (with protective cover):17.7cm
  • Diameter:2.74cm
  • Wire Length:5m
  • Connector:BNC
  • Measuring Range:0-14pH
  • Measuring Precision: ≦0.02pH
  • Suitable Temperature: 0-60℃                    
  • Response Time:10sec 
  • Drift:≦0.02PH/24hours
  • Resistance of Sensitive Membrane: ≦200*106Ω
  • Slope: ≧95 %
  • Electrode's Equipotential Point:7±0.5PH
 
Shipping List
  • H-101 pH electrode       ×1
  • pH electrode manual      ×1

Use and Maintenance

  • Electrode must be known before the measurement standard buffer solution PH value calibrated to improve the measurement accuracy , PH value of the buffer to be reliable, and the closer the measured value , the better , generally no more than three PH.
  • Sensitive glass bubble ball electrode tip is not in contact with a hard object , any breakage and hair will rub the electrode failure.
  • Electrode receptacle must be kept clean and dry height , if tarnished available medical cotton and ethanol to wipe and dry , definitely prevent the output ends of a short circuit , otherwise it will lead to inaccurate measurements or failure.
  • Measurements should be taken before the bubble inside the glass bulb rejection to , otherwise it will cause measurement errors , measurement, should stir the electrode in the test solution still placed to accelerate response.
  • Both before and after measurements and clean the electrode with deionized water to ensure measurement accuracy , the viscosity was measured in a sample , the electrodes need to use deionized water to remove the solvent.
  • Passivated electrode will produce long-term use , the phenomenon is sensitive to low gradient , slow response , inaccurate readings , then you can lower end of the electrode bulb with 0.1M solution soak for 24 hours ( preparation 0.1M dilute hydrochloric acid : 9ml hydrochloride diluted with distilled water to 1000ml), then use 3Mkcl solution soak for several hours to restore performance.
  • Glass bulb liquid surface contamination or blockage , but also make the electrode passivation , at this time , should be based on the nature of the pollutant , the appropriate cleaning solution.
  • Electrode cycle is about a year, after aging should be promptly replaced with new electrodes.

Industrial pH Electrode - Armor Casing

  • Brand: Other
  • Product Code: HAOSHI-101
  • Reward Points: 67
  • Availability: Out Of Stock
  • £80.57

  • Ex Tax: £67.14
  • Price in reward points: 700

pH Kit

pH Kit

£157.94

The Atlas Scientific pH kit comes with everything you need to get your laboratory grade embedded pH ...

Out Of Stock

pH Circuit - EZO

pH Circuit - EZO

£51.41

Atlas Scientific pH Circuit allows you to acquire scientific grade pH readings through a simple ...

Out Of Stock

pH Sensor Probe

pH Sensor Probe

£95.24

Atlas Scientific pH Sensor allows you to acquire scientific grade pH readings through a simple ...

Qty: 2

pH Analog Meter Kit

pH Analog Meter Kit

£36.89

pH Analog low cost Metering Kit

Out Of Stock

pH Analog Meter Probe

pH Analog Meter Probe

£25.02

Low cost pH probe for the pH Analog Meter Kit.

Qty: 6

pH Analog Meter Sensor Interface (PH2.0)

pH Analog Meter Sensor Interface (PH2.0)

£19.73

pH Analog Meter Sensor Interface (PH2.0)

Qty: 7

Industrial pH Kit

Industrial pH Kit

£431.93

The IXIAN class pH Transmitter is our premier technology designed exclusively for industrial ...

Out Of Stock

Industrial pH Probe

Industrial pH Probe

£237.53

A pH electrode is a passive device that detects a current generated from hydrogen ion activity.

Qty: 2